Projects

Industry 4.0 Research: OPC UA Integration

Project Overview

During my tenure as a researcher in Industry 4.0 technologies, I worked on implementing and testing OPC UA (Open Platform Communications Unified Architecture) protocols for real-time communication between sensors, edge devices, and industrial control systems. This project explored the integration of modern automation frameworks to enhance data accessibility and scalability in manufacturing environments.


Objectives

  • Enable seamless communication between a Raspberry Pi running an OPC UA server and local PCs for monitoring and control.
  • Utilize Ignition SCADA (Supervisory Control and Data Acquisition) for real-time data visualization.
  • Automate scheduled reports and dashboards displaying critical sensor data for process optimization.

Key Implementation Steps

Setting Up OPC UA Server

  • Platform: Deployed the OPC UA server on a Raspberry Pi for cost-effective edge computing.
  • Sensor Integration: Configured the server to interface with Arduino for acquiring real-time sensor data.
  • Serial Communication: Established a reliable data link between the Arduino and Raspberry Pi using Python for serial communication.

Ignition SCADA Integration

  • Visualization: Leveraged Ignition SCADA to build interactive dashboards showcasing sensor data trends.
  • Automation:
    • Configured scheduled reports to provide periodic summaries of key performance metrics.
    • Created real-time alarms and notifications for system anomalies.

Data Pipeline

  • Sensor Layer: Arduino collected environmental data such as temperature, humidity, and pressure.
  • Edge Computing Layer: Raspberry Pi processed and transmitted the data to the OPC UA server.
  • SCADA Layer: Visualized and analyzed the data through custom dashboards and reports.

Challenges and Solutions

  1. Data Latency:

    • Problem: High latency in transmitting sensor data over the serial connection.
    • Solution: Optimized serial communication by fine-tuning baud rates and implementing buffered data transmission.
  2. Integration Complexity:

    • Problem: Difficulty in integrating custom sensor data with Ignition's default OPC UA modules.
    • Solution: Wrote custom scripts in Python and configured Ignition's tag historian for seamless data logging.
  3. Scalability:

    • Problem: Limited scalability of the Raspberry Pi server for large datasets.
    • Solution: Explored modular architectures to allow for distributed computing in future implementations.

Results

  • Successfully demonstrated a real-time data monitoring system using OPC UA and Ignition SCADA.
  • Enabled predictive analytics by logging sensor data trends and generating actionable insights.
  • Automated reporting reduced manual intervention and improved process reliability.

Recommendations for Future Work

  • Advanced Analytics:
    • Integrate machine learning models for predictive maintenance and anomaly detection.
  • Scalability:
    • Migrate to industrial-grade hardware or cloud-based OPC UA servers to handle larger data volumes.
  • Expanded Device Support:
    • Explore compatibility with additional industrial protocols such as Modbus or EtherNet/IP.

Figures to Include

  1. Figure 1: Architecture of the OPC UA integration.
  2. Figure 2: Sample SCADA dashboard visualizing sensor trends.
  3. Figure 3: Serial communication diagram between Arduino and Raspberry Pi.
Return to Portfolio